Configuring GVRP

Configuring GVRP
Functions
Configuring GARP
Timers
n
GVRP can only be configured at the Trunk port.
GVRP configuration is broken down into: configuring GVRP functions and

configuring GARP timers.

Follow these steps to configure GVRP functions on a trunk port:
To do...
Enter system view
Enable global GVRP
Enter Ethernet
Enter Ethernet
interface view
interface view
or port group
Enter port
view
group view
Enable GVRP
Set the GVRP registration
mode
Follow these steps to configure GARP timers:
To do...
Enter system view
Configure the GARP LeaveAll
timer
Enter Ethernet
Enter Ethernet
interface view
interface view
or port group
Enter port
view
group view
Set the hold timer, join timer,
and leave timer
As for the GARP timers, note that:
Use the command...
system-view
gvrp
interface interface-type
interface-number
port-group { aggregation
agg-id | manual
port-group-name }
gvrp
gvrp registration { fixed |
forbidden | normal }
Use the command...
system-view
garp timer leaveall
timer-value
interface interface-type
interface-number
port-group { aggregation
agg-id | manual
port-group-name }
garp timer { hold | join |
leave } timer-value
Configuring GVRP
275
Remarks
--
Required
Disabled by default
Use either the command.
Configured in Ethernet
interface view, the
subsequent configuration is
effective on the current port
only; configured in port
group view, the subsequent
configuration is effective on
all ports in the port group.
Required
Disabled by default
Optional
The default is normal.
Remarks
--
Optional
The default is 1000
centiseconds.
Use either the command
Configured in Ethernet
interface view, the
subsequent configuration is
effective on the current port
only; configured in port
group view, the subsequent
configuration is effective on
all ports in the port group.
Optional
The default is 10 centiseconds
for the hold timer, 20
centiseconds for the join
timer, and 60 centiseconds
for the leave timer.