Complex Spectrum Measurement
Meas Setup
Notes
Dependencies
Couplings
Preset
State Saved
Min
Max
Channel Filter Bandwidth Bwcc (Remote Command Only)
This is the backward compatibility command for Filter Bandwidth.
Mode
Remote Command
Example
Notes
Dependencies
Couplings
Preset
State Saved
Min
Max
Channel Filter Alpha
Sets the filter alpha for the DIF filter. This feature is only available with PXA or when Option B40 is
installed.
Key Path
Mode
252
You must be in the IQ Analyzer (Basic) mode to use this command. Use
INSTrument:SELect to set the mode.
This feature is only available with PXA or when Option B40 is installed.
Sets the same value as the current Digital IF BW value upon a preset or when
Channel Filter Bandwidth Auto is ON.
Same value as Digital IF BW
ON
Saved in instrument state.
10 Hz
Clipped to the current Digital IF BW value.
BASIC
[:SENSe]:SPECtrum:WBIF:FILTer:BANDwidth <real>
[:SENSe]:SPECtrum:WBIF:FILTer:BANDwidth?
SPEC:WBIF:FILT:BAND 0.3
SPEC:WBIF:FILT:BAND?
You must be in the IQ Analyzer (Basic) mode to use this command. Use
INSTrument:SELect to set the mode.
This feature is only available with PXA or when Option B40 is installed.
The value is determined by the following equation.
ChannelFilterBwBwcc =
(ChannelFilterBw/(DigitalIFBw*OverSampleRatio))
0.8
Saved in instrument state.
0.01
1.0
Meas Setup, Advanced