Agilent Technologies X Series Manual page 154

Signal analyzer
Hide thumbs Also See for X Series:
Table of Contents

Advertisement

System Functions
System
Remote Command
Example
Notes
Preset
Preset
State Saved
Initial S/W Revision
Configure Applications
The Configure Applications utility lets you do two things:
1. specify a subset of the available applications (Modes) to preload into memory at startup time
2. specify the order in which the Modes appear in the Mode menu
There are several reasons you might want to specify a subset of the available applications (Modes) to
preload:
• During runtime, if a Mode which is not preloaded is selected by the user, there will be a pause while
the Application is loaded. Configure Applications lets you decide whether you want that delay at
startup of the analyzer program or the first time you select the Mode.
• In addition, there are more applications available for the X-Series than can fit into Windows Virtual
Memory. The Configure Application utility allows you to choose which licensed applications to load
into memory, if you have more licensed than can fit.
The Configure Applications utility can be used to select applications for preload and/or to determine how
many applications can fit in memory at one time. This utility consists of a window with instructions, a set
of "Select Application" checkboxes, a "fuel bar" style memory gauge, and softkeys that help you set up
your configuration.
Preloading Applications
During operation of the analyzer, you select applications from the Mode menu. After startup of the
analyzer program, the first time you select a particular application that application must be loaded into
memory. Once loaded, the application stays loaded, so the next time you select it during a session, there
is no delay. During runtime, if an application which is not yet loaded into memory is selected using the
Mode menu or sending SCPI commands, there will be a pause while the Application is loaded. During
this pause a message which says "Loading application, please wait ..." is displayed.
You can use the Configure Applications utility to choose applications to "preload" at startup, to eliminate
the runtime delay; if you do this, the delay will instead increase the time it takes to start up the analyzer
program, but for many users this is preferable to having to wait the first time they select an application.
154
:SYSTem:PON:MODE
SA|BASIC|ADEMOD|NFIGURE|PNOISE|CDMA2K|TDSCDMA|VSA|VSA89
601|WCDMA|WIMAXOFDMA
:SYSTem:PON:MODE?
SYST:PON:MODE SA
The list of possible modes (and remote parameters) to choose from is
dependent on which modes are installed in the instrument.
SA
This is unaffected by a Preset but is set on a "Restore System Defaults->All"
to SA.
No
Prior to A.02.00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

N9030aN9020aN9010aN9000aN9038a