Parameter Definition - Delta ASDA-B2-F Series User Manual

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

Parameters

7.1 Parameter Definition

Parameters are divided into five groups which are shown as follows. The first character after the
start code P is the group character and the following two characters are parameter character.
7
As for the communication address, it is the combination of group character along with two digit
numbers in hexadecimal format. The definition of parameter groups is as the followings:
Group 0: Monitor parameters
Group 1: Basic parameters
Group 2: Extension parameters
Group 3: Communication parameters
Group 4: Diagnosis parameters
Group 5: Motion control parameters (example: P5-xx)
Control Mode Description
Sz: Speed control mode
Tz: Torque control mode
DMC: DMCNET control mode
Special Symbol Description
(★)
(▲)
( ● )
( ■ )
7-2
Read-only register, can only read the status. For example: P0-00, P0-10 and P4-00,
etc.
Setting is invalid when Servo On, e.g. P1-00, P1-46 and P2-33, etc.
Not effective until re-power on or off the servo drive, e.g. P1-01 and P3-00.
Parameters of no data retained setting, e.g. P2-31 and P3-06.
(example: P0-xx)
(example: P1-xx)
(example: P2-xx)
(example: P3-xx)
(example: P4-xx)