Delta ASDA-B2-F Series User Manual page 242

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

ASDA-B2-F
Watt/Kilowatt
Digital Input/Output
Protective Function
Communication Interface
Installation Site
Altitude
Atmospheric Pressure
Ambient Temperature
Storage Temperature
Humidity
Vibration
IP Rating
Power System
Approvals
Note:
*1
With
rated load, the speed ratio is: the minimum speed (smooth operation) / rated speed.
*2 When the command is the rated speed, the velocity correction ratio is: (rotation speed without load –
rotation speed with full load) / rated speed.
*3 Please refer to page A-16 for overload features.
*4 TN system: The neutral point of the power system connects to the ground directly. The exposed metal
components connect to the ground via protective earth conductor.
*5 2 kW, 3 kW models are scheduled to be released.
September, 2015
100
200
01
02
Alarm
reset, Gain switching, Speed command selection, Emergency
stop, Forward/Reverse inhibit limit and Forward/Reverse operation
torque limit.
Input
*DIs mentioned above are only available for Non-DMCNET mode. In DMCNET
mode, it is suggested to use communication for DI input and DI functions of
emergency stop, forward/reverse inhibit limit and homing.
A, B Line Driver output
Servo ready, Servo on, Zero speed reached, Target speed reached,
Output
Target position completed, Torque limiting, Servo alarm, Brake control,
Early warning for overload, Servo warning
Over current, Over voltage, Under voltage, Overheat, Overload*
Excessive speed deviation, Excessive position deviation, Encoder
error, Regeneration error, Communication error, Register error,
Short-circuit protection of terminal U, V, W and CN1, CN2, CN3
Indoors (avoid direct sunlight), no corrosive fog (avoid fume,
flammable gas and dust)
o
o
0
C ~ 55
C (If ambient temperature is above 45
be required)
400
750
1 k
04
07
10
RS-232
1000 m or lower (above sea level)
86 kPa ~ 106 kPa
o
o
-20
C ~ 65
C
0 ~ 90% RH below (non-condensing)
2
9.80665 m/s
(1 G), less than 20 Hz
2
5.88 m/s
(0.6 G), 20 to 50 Hz
IP20
*4
TN system
IEC/EN 61800-5-1, UL508C
Appendix A Specifications
1.5 k
2 k
3 k
15
20
30
3
,
o
C, forced cooling will
A
A-3