Delta ASDA-B2-F Series User Manual page 129

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

Parameters
P0-03~P0-07
P0-08★
7
Operational
Interface:
Default: 0
Format: DEC
Settings:
It shows the total start up time of the servo drive.
P0-09★
Operational
Interface:
Default: -
Format: DEC
Settings:
The setting value which is set by P0-17 should be monitored via P0-09. (Please refer to P0-02).
Users need to access the address via communication port to read the status.
For example:
If P0-17 is set to 3, when accessing P0-09, it obtains the total feedback pulse number of motor
encoder. For MODBUS communication, two 16-bit
32-bit data; (0013H:0012H) = (Hi-word:Low-word) Set P0-02 to 23. The panel displays "VAR-1"
first, and then shows the content of P0-09.
P0-10★
Operational
Interface:
Default: -
Format: DEC
Settings:
The setting value which is set by P0-18 should be monitored via P0-10. (Please refer to P0-02)
Users need to access the address via communication port to read the status. Set P0-02 to 24. The
panel displays "VAR-2" first, and then shows the content of P0-10.
P0-11★
Operational
Interface:
Default: -
Format: DEC
Settings:
The setting value which is set by P0-19 should be monitored via P0-11. (Please refer to P0-02)
Users need to access the address via communication port to read the status. Set P0-02 to 25. The
panel displays ‟VAR-3" first, and then shows the content of P0-11.
P0-12★
Operational
Interface:
Default: -
Format: DEC
Settings:
7-12
Reserved
TSON
Power On Time
Panel / Software
Communication
Unit: Hour
CM1
Status Monitor Register 1
Panel / Software
Communication
Unit: -
CM2
Status Monitor Register 2
Panel / Software
Communication
Unit: -
CM3
Status Monitor Register 3
Panel / Software
Communication
Unit: -
CM4
Status Monitor Register 4
Panel / Software
Communication
Unit: -
Address: 0010H
Related
-
Section:
Control
-
Mode:
Range: 0 ~ 65535
Data Size: 16-bit
Address: 0012H
Related
4.3.5
Section:
Control
ALL
Mode:
Range: -
Data Size: 32-bit
data,
0012H and 0013H will be read as one
Address: 0014H
Related
4.3.5
Section:
Control
ALL
Mode:
Range: -
Data Size: 32-bit
Address: 0016H
Related
4.3.5
Section:
Control
ALL
Mode:
Range: -
Data Size: 32-bit
Address: 0018H
Related
3.3.5
Section:
Control
ALL
Mode:
Range: -
Data Size: 32-bit
ASDA-B2-F
0011H
0013H
0015H
0017H
0019H
September, 2015