Parameters
7
Following describes the setting value of P1-52 and P1-53 when connecting regenerative resistor
with different method:
P1-54
Operational
Interface:
Default: 12800
Format: DEC
Settings:
In DMCNET mode, if the deviation pulse number is smaller than the setting range (the setting
value of parameter P1-54), DO.TPOS is ON.
P1-55
Operational
Interface:
Default:
Format: DEC
Settings:
The default of the max. speed of servo motor is set to the rated speed.
7-34
1.5 kW
60
2 kW
100
3 kW
100
External regenerative resistor
P
1 kW, 10 Ω
C
External regenerative resistor
(serial connection)
P
1 kW, 10 Ω
1 kW, 10 Ω
C
External regenerative resistor
(parallel connection )
P
1 kW, 10 Ω
C
PER
Position Completed Range
Panel / Software
Communication
Unit: Pulse
MSPD
Maximum Speed Limit
Panel / Software
Communication
Same as the rated speed of each
model.
Unit: r/min
Setting:
P1-52 = 10 (Ω)
P1-53 = 1000 (W)
Setting:
P1-52 = 20 (Ω)
P1-53 = 2000 (W)
Setting:
P1-52 = 5 (Ω)
1 kW, 10 Ω
P1-53 = 2000 (W)
Related
Section:
Control
Mode:
Range: 0 ~ 1280000
Data Size: 32-bit
Related
Section:
Control
Mode:
Range: 10 ~ max.speed
Data Size: 16-bit
Address: 016CH
016DH
Table 7.2
DMCNET
Address: 016EH
016FH
-
ALL
ASDA-B2-F
September, 2015