Delta ASDA-B2-F Series User Manual page 75

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

Trial Operation and Tuning
If the function of positive limit (PL) is needed and this DI is set as normally close (function
code: 0x0023), please make sure this DI is always normally close. If not, please set this DI
as normally open (function code: 0x0123).
5
(6) When screen displays
Warning of overcurrent:
Corrective action:
Check the connection between the motor and servo drive.
Check if the conducting wire is short circuited.
Exclude short circuit and avoid metal conductors being exposed.
(7) When screen displays
Warning of undervoltage:
Corrective action:
Check if the wiring of main circuit input voltage is correct.
Use voltmeter to measure if the main circuit voltage is normal.
Use voltmeter to measure if the power system complies with the specification.
Note:
During power on or servo on (without issuing any command), if an alarm occurs or any abnormal display is
shown, please contact the distributors.
5-6
ASDA-B2-F
September, 2015