Delta ASDA-B2-F Series User Manual page 85

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

Trial Operation and Tuning
5
Note:
1. Resonance suppression is determined by parameter P2-44 and P2-46. If the value has been set to the
maximum (32 dB), and still cannot suppress the resonance, please reduce the speed bandwidth. After
setting P2-47, users can check the value of P2-44 and P2-46. If the value of P2-44 is not 0, it means the
resonance frequency exists in the system. Then, users can access P2-43 to see the resonance
frequency (Hz). When there is another resonance frequency, the information will be shown in P2-45 and
P2-46.
2. If resonance still exists, repeatedly set P2-47 to 1 for more than 3 times and manually adjust the setting of
resonance.
5-16
Motor alternately accelerates
and decelerates
No
High-frequency
resonance?
Yes
Set P2-47 to 1
No
Resonance
elimminated?
Yes
Set P2-47 to 0
Complete
Figure 5-6 Procedure of auto suppressing the resonance
Complete
No
Repeatedly set P2-47
to 1 for over 3 times
Note 1
Yes
No
P2-44 = 32 (max);
P2-46 = 32 (max)
Note 2
Yes
It is suggested to reduce the
speed bandwidth.
P2-47 is set to 0
Remain the value of P2-43
and P2-45
Suppress resonance by P2-
44 and P2-46.
Motor alternately accelerates
and decelerates
Yes
High-frequency
resonance?
No
ASDA-B2-F
September, 2015