Parameters
Settings:
0: Manual Mode
1: Auto Mode (continuous adjustment)
2: Semi-auto Mode (non-continuous adjustment)
7
Description of manual mode setting:
When P2-32 is set to 0, parameters related to gain control, such as P2-00, P2-02, P2-04, P2-06,
P2-07, P2-25 and P2-26, all can be set by the user. When switching mode from auto or semi-auto
mode to manual mode, gain-related parameters will be updated automatically.
Description of auto mode setting:
Continue to estimate the system inertia. Automatically save the load inertia ratio to P1-37 every 30
minutes and refer to the stiffness and bandwidth setting of P2-31.
1. Set the system to manual mode 0 from auto mode 1 or semi-auto mode 2. The system will save
2. Set the system to auto mode 1 or semi-auto mode 2 from manual mode 0. Please set appropriate
3. Set the system to manual mode 0 from auto mode 1. P2-00, P2-04 and P2-06 will be modified to
4. Set the system to manual mode 0 from semi-auto mode 2. P2-00, P2-04, P2-06, P2-25 and P2-26
Description of semi-auto mode setting:
1. When the system inertia is stable, the value of P2-33 will be 1 and the system stops estimating.
2. When the system inertia is over the range, the value of P2-33 will be 0 and the system starts to
P2-33▲
Operational
Interface:
Default: 0
Format: DEC
Settings:
Semi-auto Setting:
1: It means the inertia estimation in semi-auto mode is completed. The inertia value can be
accessed via P1-37.
0: When the display is 0, it means the inertia adjustment is not completed yet and is still adjusting.
When the setting is 0, it means the inertia adjustment is not completed yet and is still adjusting.
P2-34
Operational
Interface:
Default: 5000
Format: DEC
Settings:
It is the setting for over speed warning in servo drive error display (P0-01).
7-44
the estimated load inertia value to P1-37 automatically and set the corresponding parameters.
load inertia value in P1-37.
the corresponding parameters in auto mode.
will be modified to the corresponding parameters in auto mode.
The load inertia ratio will be saved to P1-37 automatically. When switching from other modes to
semi-auto mode (from manual mode or auto mode), the system starts to estimate again.
estimate and adjust again.
AUT3
Semi-auto Inertia Adjustment
Panel / Software
Communication
Unit: -
SDEV
Condition of Over Speed Warning
Panel / Software
Communication
Unit: r/min
Related
Section:
Control
Mode:
Range: 0 ~ 1
Data Size: 16-bit
Semi-auto setting
Reserved
Not in use
Related
Section:
Control
Mode:
Range: 1 ~ 5000
Data Size: 16-bit
Address: 0242H
0243H
-
ALL
Address: 0244H
0245H
-
Sz