Delta ASDA-B2-F Series User Manual page 215

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

Troubleshooting
AL235
PR command overflows
9
AL245
PR positioning is over time.
AL283
Forward software limit
AL285
Reverse software limit
9-14
PR command overflows
Causes
Incremental Type:
Continuous operation in one direction in
PR mode causes position feedback
register (FB_PUU) overflows. Thus, the
coordinate system cannot reflect the
correct position. If issuing the absolute
positioning command at this moment,
the error will occur.
Absolute Type:
If issuing the absolute positioning
command in the following situations, this
error will occur:
1. Feedback position register
(FB_PUU) overflows.
2. When P1-01.Z is modified, homing
has not been completed yet.
3. When electronic gear ratio (P1-44,
P1-45) is modified, homing has not
been completed yet.
4. Function of returning to the original
point is triggered and homing has
not completed yet.
5. AL060 and AL062 occur.
PR positioning is over time
Causes
N/A
Forward software limit
Causes
Forward software limit is determined by
position command, not the actual
feedback position. That is because the
command always arrives first and then
the feedback. When the protection
function is activated, the actual position
might not exceed the limit yet.
Therefore, setting an appropriate
decelerating time could satisfy the
demand. Please refer to the description
of P5-03.
Reverse software limit
Causes
Reverse software limit is determined by
position command, not the actual
feedback position. That is because the
command always arrives first and then
the feedback. When the protection
function is activated, the actual position
might not exceed the limit yet.
Therefore, setting an appropriate
decelerating time could satisfy the
demand. Please refer to the description
of P5-03.
Conduct homing to clear this alarm
Checking Method
N/A
Checking Method
Issue alarm reset to clear this alarm
Checking Method
Issue alarm reset to clear this alarm
Checking Method
Corrective Actions
Conduct homing
Corrective Actions
If this alarm occurs, please directly
send the servo drive back to Delta
without making any modification.
Corrective Actions
Issue alarm reset
Corrective Actions
Issue alarm reset
ASDA-B2-F
September, 2015

Hide quick links:

Advertisement

Table of Contents
loading