Panel Display and Operation
4.4.3 Force DO On
Enter the Diagnosis Mode by the following settings. Set P2-08 to 406 and enable the function of
force DO on. Then, set the forced DO by binary method via P4-06. When the setting value is 2, it
4
will force to enable DO2. When the setting value is 5, it will force to enable DO1 and DO3. No
data is retained in this mode. It returns to the normal DO mode when re-power on the drive or set
P2-08 to 400.
Note:
P4-06 is displayed in hexadecimal format. Therefore, it will not show the fifth 0.
4-12
SET
SET
Force to enable
DO mode
SET
Force to enable DO1
Force to enable DO2
Force to enable DO1 and DO2