Delta ASDA-B2-F Series User Manual page 63

Economic ac servo drive with dmcnet communication
Table of Contents

Advertisement

Panel Display and Operation
P0-02
Setting
Value
13
4
14
15
16
17
18
19
20
21
22
23
24
25
26
4-8
Monitor Displayed
Symbol
Peak torque
Main circuit voltage
Load / Motor inertia ratio (Note: If it shows 13.0, it
means the actual inertia is 13)
IGBT temperature
Resonance frequency (Low byte is the first resonance
and high byte is the second one).
The absolute pulse number of encoder Z phase equals
0
0
+5000,
+5000, 0
the homing value, 0. It will be +5000 or -5000 pulse
when rotating in forward or reverse direction.
Z
Z
Z
Mapping parameter #1: shows the content of parameter
P0-25 (specify the mapping target by P0-35)
Mapping parameter #2: shows the content of parameter
P0-26 (specify the mapping target by P0-36)
Mapping parameter #3: shows the content of parameter
P0-27 (specify the mapping target by P0-37)
Monitor variable #4: shows the content of parameter
P0-28 (specify the monitor variable code by P0-38)
Monitor variable #1: shows the content of parameter
P0-09 (specify the monitor variable code by P0-17)
Monitor variable #2: shows the content of parameter
P0-10 (specify the monitor variable code by P0-18)
Monitor variable #3: shows the content of parameter
P0-11 (specify the monitor variable code by P0-19)
Monitor variable #4: shows the content of parameter
P0-12 (specify the monitor variable code by P0-20)
Description
ASDA-B2-F
Unit
[%]
[Volt]
[1 times]
[°C]
[Hz]
-
-
-
-
-
-
-
-
-
September, 2015