Kidde ARIES Installation, Operation And Maintenance Manual page 93

Fire alarm/suppression
Table of Contents

Advertisement

Set
1. Time / Date
2. Port Control
1. Set Time
1. RS232 A *
1. AM / PM
1: PRINTER
System Time (AM / PM 1 - 12 Hrs)
3: ICM
Enter the Time *_:_ _ (HH:MM)
1: AM
2: PM *
2. RS232 B *
2. Military
1: PRINTER
3: ICM
Set Time (Mil 1 - 24 Hrs))
Enter the Time *_:_ _ (HH:MM)
2. Set Date
Set Date
Enter the Date *_-__- __ (MM-DD-YY)
amming
1. Day / Night
2. Passwords
1. Owner's
1. Set Detectors
Set Day / Night / Weekend Mode
Change Owner Password
SLC Devices From *_ _ to _ _ _
(1 - 255)
Enter New Password
Re-Enter New Password *________
Day / Night / Weekend Mode
1. Activate 2. De-Activate *
2. Installer's
2. Set Periods
Change Installer Password
Enter New Password
Set Day Period (Now 08:00)
Day Period Start *_:__ (24 hour clock)
Set Night Period (Now 18:00)
Night Period Start *_:__ (24 hour clock)
3. Get MFG Code
3. Activate
Nighttime Settings at Night
1. Activate 2. De-Activate *
Nighttime Settings on Weekend
1. Activate 2. De-Activate *
P/N 06-236530-001
3. SLC Devices
1. Device Addr Change
2. Configuration
3. Registration
Set Loop Device Address
Present Loop Device Address*_ _
(1 - 255)
2: IIM
Set Target Loop Address
*_ _
(1 - 255)
0: NOT USED *
1. Ionization
2: IIM
0: NOT USED *
1. Alarm
1. Fixed Settings
2. Day/Night Settings
2. Supervisory
Set Detector Sensitivity
SLC Devices From * _ _ to _ _ _
3. AutoLearn
4. AutoSetup
5. Alarm Verification
*_______
Assign Alarm Verification
1: Enable
2: Disable
6. Positive Alarm Sequence
*_______
Re-Enter New Password *________
Assign Positive Alarm Sequence
1: Enable
2: Disable
7. Clear Events
Event Log Clear
1: Clear Events
2: Exit *
8. Clear Tests
1. Clear SLC Tests *
Clearing SLC Test Results
SLC Devices From *_ _ to _ _ _
(1 - 255)
2. Clear Walk Tests *
Clearing Walk Test Results
SLC Devices From *_ _ to _ _ _
(1 - 255)
9. Resynch. Network
5. Blink Control
4. De-Registration
Device Registration
Device De-Registration
SLC Devices From *_ _ to _ _ _
(1 - 255)
SLC Devices From *_ _ to _ _ _
(1 - 255)
2. Photoelectric
1. Alarm
1. Fixed Settings
Set Detector Sensitivity
Set Detector Sensitivity
SLC Devices From * _ _ to _ _ _
(1 - 255)
SLC Devices From * _ _ to _ _ _
Set Detector Sensitivity
Set Detector Sensitivity
1: Open Area
2: In Duct
3: DH-2000 *
1: Open Area
2: In Duct
Set Detector Sensitivity
Set Detector Sensitivity
Pre-Alarm Level
*._
(0.5 - 1.4) %/Ft.
Pre-Alarm Level
Set Detector Sensitivity
Set Detector Sensitivity
Alarm Level
*._
(0.5 - 1.5) %/Ft.
Alarm Level
2. Day/Night Settings
Set Detector Sensitivity
Set Detector Sensitivity
(1 - 255)
SLC Devices From * _ _ to _ _ _
SLC Devices From * _ _ to _ _ _
Set Detector Sensitivity
Set Detector Sensitivity
1: Open Area
2: In Duct
3: DH-2000 *
1: Open Area
2: In Duct
Set Detector Sensitivity
Set Detector Sensitivity
Pre-Alarm Level
*._
(0.5 - 1.4) %/Ft.
Pre-Alarm Level
Set Detector Sensitivity
Set Detector Sensitivity
Day Alarm Level
*._
(0.5 - 1.5) %/Ft.
Day Alarm Level
Set Detector Sensitivity
Night Alarm Level *._
(0.5 - 1.4) %/Ft.
2. Supervisory
Set Detector Sensitivity
(1 - 255)
SLC Devices From * _ _ to _ _ _
Set Detector Sensitivity
Set Detector Sensitivity
1: Open Area
2: In-Duct / DH-2000 *
1: Open Area
2: In-Duct / DH-2000 *
1. Fixed Settings
1. Fixed Settings
Set Detector Sensitivity
Set Detector Sensitivity
Alarm Level
*._
(0.5 - 1.5) %/Ft.
Alarm Level
2. Day / Night Settings
2. Day / Night Settings
Set Detector Sensitivity
Set Detector Sensitivity
Day Alarm Level
*._
(0.5 - 1.5) %/Ft.
Day Alarm Level
Set Detector Sensitivity
Set Detector Sensitivity
Night Alarm Level *._
(0.5 - 1.4) %/Ft.
Night Alarm Level *._
5. Globals
6. Network
1. Style
1. Global Acknowledge
Change Style
1: Ch1
2: Ch2
3. Both
Global Acknowledge of Trouble/Supv
Change Style
Acknowledge - (1)
Deactivate - (0) *
1: Enable 2: Disable
2. Node Number
2. Alarm Verification
Change Node Number
1: Range (1 to 32) 2: Standalone
Assign Alarm Verification
Verification Period *_ (060 - 180 Seconds)
3. Group
Change Group
1: Group (1 to 32) 2: Not Grouped
4. Add/Remove Nodes
3. PAS
Add/Remove Network Nodes
1: Add
2: Remove
Set Delay Period in Seconds
Add/Remove Network Nodes
*_ (Max. 180 Seconds)
Nodes: *__ to __
5. Reset Event
Positive Alarm Sequence
Activate - (1)
Deactivate - (0) *
Change Network Reset
1: Enable
2: Disable
6. Silence Event
4. Central Station
Change Network Silence
1: Enable
2: Disable
Central Station Operation
Activate - (1)
Deactivate - (2) *
7. Log Events
Log All Events or Only Log Group Events
1: Log All Events 2: Log Group Events
5. Global Alarm Ack
8. Time Synch Period
Global Acknowledge of Alarms
Activate - (1)
Deactivate - (2) *
Change Time Synch
Period: 0 (Off) or 600-32767 Sec ____
9. Isolate
Isolate/De-isolate Node
1: Isolate
2: De-isolate
Figure 3-6. Menu Functions Cont.
3-11 (Page 3-12 blank)
5. Replace Device
Program Device Blink Control
Present SLC Device Address *_ _
(0 - 255)
SLC Devices From *_ _ to _ _ _
(1 - 255)
SLC Device Addr to Change *_ _
(1 - 255)
Set Blink Control
1: Blink Off
2: Blink On
1: Keep Current Settings
3 Thermal
4 Alarmline
Set Detector Sensitivity
SLC Devices From *_ _ to _ _ _
(1 - 255)
Set AAM Configuration
SLC Devices From *_ _ to _ _ _
Set Detector Sensitivity
1: 50 Ft. *
(1 - 255)
Set Detector Sensitivity
3: DH-2000 *
Pre-Alarm Level
*__
(80 - 154)
Set Detector Sensitivity
*._
(0.2 - 3.4) %/Ft.
Alarm Level
*__
(135 - 155)
*._
(0.5 - 3.5) %/Ft.
Set Detector Sensitivity
2: 70 Ft. *
Set Detector Sensitivity
Pre-Alarm Level
*__
(80 - 144)
(1 - 255)
Set Detector Sensitivity
Alarm Level
*__
(135 - 145)
3: DH-2000 *
*._
(0.2 - 3.4) %/Ft.
*._
(0.5 - 3.4) %/Ft.
Set Detector Sensitivity
*._
(0.5 - 3.5) %/Ft.
Night Alarm Level
*._
(0.5 - 3.4) %/Ft.
(1 - 255)
*._
(0.5 - 3.5) %/Ft.
*._
(0.5 - 3.5) %/Ft.
(0.5 - 3.4) %/Ft.
7. Control Modules
8. HSDs
1. Register
1. Register IIM
Register Control / Display Module
1: ATM
2: RDCM *
2. De-register IIM
1: Enter the ATM Number to Register
ATM: *_
2: Enter the RDCM Number to Register
RDCM: *_
3. Register HSDs
4. De-register HSDs
2. De-Register
De-Register Control / Display Module
1: ATM
2: RDCM *
1. Enter the ATM Number to De-Register
ATM: *_
2. Enter the RDCM Number to De-Register
RDCM: *_
3. Reset ATM / RDCM
Reset Control Module
1: Reset
2: Exit *
System Operations
2: Set Default
5 Remote Release
Set RRM Configuration
(1 - 255)
SLC Devices From *_ _ to _ _ _
(1 - 255)
Set AAM Configuration
Switch Setting
1 to 16 *_
Set RRM Configuration
1: Solenoid
2: Actuator *
Set AAM Configuration
Pre-Alarm
1: ON
2: OFF *
Set AAM Configuration
Alarm
1: Normal
2: Overheat *
9. Battery
1. Battery Disp Enable
Register IIM On Port
2. Battery Disp Disable
1: RS232A
2: RS232B
3. Disable Battery
Disable IIM On Port
1: Confirm
2: Cancel
HSD Registration
HSD Devices From ___ to ___ (1 - 127)
HSD De-registration
HSD Devices From ___ to ___ (1 - 127)
Legend
Level-2 (Installer) Password required.