List Of Figures - Kidde ARIES Installation, Operation And Maintenance Manual

Fire alarm/suppression
Table of Contents

Advertisement

Figure
Name
1-1
Typical ARIES System .......................................................................................... 1-1
1-2
ARIES Display ..................................................................................................... 1-3
1-3
ARIES Control Unit Printed Circuit Board ................................................................. 1-5
1-4
ARIES Cabinet ..................................................................................................... 1-6
1-5
Power-Supply Assembly........................................................................................ 1-7
1-6
Remote Display/Control Module ............................................................................. 1-7
1-7
Model ATM-R Relay Driver Module .......................................................................... 1-8
1-8
Network Interface Card (shown mounted to PCB) ..................................................... 1-9
1-9
Intelligent Interface Module................................................................................... 1-9
1-10
Fiber Optic Converter Card .................................................................................... 1-10
1-11
Trim Ring ........................................................................................................... 1-10
1-12
SmartOne™ Smoke Detector ................................................................................. 1-11
1-13
THD-7252 Thermal Detector.................................................................................. 1-11
1-14
6SB Detector Base (Flanged)................................................................................. 1-12
1-15
4SB Detector Base (Flangeless) ............................................................................. 1-12
1-16
MA-002 Detector Base Adapter .............................................................................. 1-12
1-17
DH-2000 Duct-Detector Housing ............................................................................ 1-13
1-18
AI Monitor Module................................................................................................ 1-14
1-19
ORION-XT Interface Module .................................................................................. 1-14
1-20
Addressable AlarmLine Module............................................................................... 1-14
1-21
AO Relay Module ................................................................................................. 1-15
1-22
ASM Addressable Signal Module ............................................................................. 1-15
1-23
Remote Releasing Module ..................................................................................... 1-16
1-24
Isolator Modules .................................................................................................. 1-17
2-1
Enclosure Dimensions........................................................................................... 2-5
2-2
Back Box Mounting Dimensions ............................................................................. 2-6
2-3
Semi-Flush Mounting Dimensions........................................................................... 2-7
2-4
Power Supply Unit ............................................................................................... 2-8
2-5
Primary Power Selection Switch ............................................................................. 2-9
2-6
PCB Installation ................................................................................................... 2-10
2-7
PCB-to-Cabinet Grounding Diagram........................................................................ 2-11
2-8
Primary-Power Connections................................................................................... 2-12
2-9
Standby Battery Connections................................................................................. 2-13
2-10
Measuring Class-B SLC Wiring Resistance................................................................ 2-14
2-11
Measuring Class-B SLC Wiring Capacitance.............................................................. 2-14
2-12
Class-B, Style-4 Signaling Line Circuit .................................................................... 2-15
2-13
Measuring Class-A SLC Wiring Resistance................................................................ 2-16
2-14
Measuring Class-A SLC Wiring Capacitance.............................................................. 2-16
2-15
Class-A, Style-6 Signaling Line Circuit .................................................................... 2-17
2-16
Class-A, Style-7 Signaling Line Circuit .................................................................... 2-18
2-17
Class-A, Style-Z Notification-Appliance Circuit.......................................................... 2-19
2-18
Class-B, Style-Y Notification-Appliance Circuit.......................................................... 2-19
2-19
Wiring Length vs. Notification-Appliance Current ...................................................... 2-20
2-20
Combination Circuit used as Class-A, Style-Z NAC .................................................... 2-21
2-21
Combination Circuit used as Class-B, Style-Y NAC .................................................... 2-21
2-22
Combination Circuit used as Releasing Circuit .......................................................... 2-22
2-23
Releasing-Circuit Wiring for Actuator ...................................................................... 2-23
2-24
Releasing-Circuit Wiring for Single Solenoid............................................................. 2-23
2-25
Releasing-Circuit Wiring for Dual Solenoids ............................................................. 2-24
2-26
Auxiliary-Power Terminals..................................................................................... 2-25
2-27
Single-Channel RS-485 Wiring to Peripheral Devices................................................. 2-26
2-28
Dual-Channel RS-485 Wiring to Peripheral Devices ................................................... 2-27
2-29
24 Vdc-Power Wiring Length vs. Peripheral-Devices Current ...................................... 2-28
P/N 06-236530-001

LIST OF FIGURES

xiii
Page Number
August 2013

Advertisement

Table of Contents
loading

Table of Contents