Clean The Fuel Pump Strainer - Deutz Diesel Models - Genie S-60 Service Manual

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Section 4 • Scheduled Maintenance Procedures
TABLE D PROCEDURES
8 Fill the engine with new oil per specifications
and install the oil filler cap.
9 Start the engine from the ground controls. Allow
the engine to run for 30 seconds then turn the
engine off.
10 Check the oil filter and drain hose for leaks.
11 Check the engine oil level dipstick. Add oil if
needed.
Deutz F4l 1011 Engine
Oil capacity (including filter)
Oil viscosity requirements
below 60°F / 15.5°C (synthetic)
-10°F to 90°F / -23°C to 32°C
above -4°F / -34°C
Engine oil should have properties of API classification
CC/SE or CC/SF grades.
Oil filter - Genie part number
4 - 68
D-8
Clean the Fuel Pump Strainer -
Deutz Diesel Models
Cleaning the fuel pump strainer is essential for
good engine performance and service life. A dirty
or clogged strainer may cause the engine to
perform poorly and continued use may cause
11 quarts
component damage. Extremely dirty conditions or
10.5 liters
not operating the machine for extended periods of
time may required that the strainer be cleaned
more often.
5W-30
10W-40
15W-40
49924
1 Open the engine side turntable cover and locate
the fuel pump, located next to the engine oil dip
stick.
2 Turn the manual fuel shutoff valve, located at
the fuel tank, to the
Genie S-60 & Genie S-65
Third Edition • First Printing
Explosion and fire hazard. Engine
fuels are combustible. Perform this
procedure in an open, well-
ventilated area away from heaters,
sparks, flames and lighted
tobacco. Always have an
approved fire extinguisher within
easy reach.
Perform this procedure with the
engine off.
Immediately clean up any fuel that
may have spilled during this
procedure.
position.
CLOSED
Part No. 65196