Section 5 • Troubleshooting Flow Charts
Chart 34
Machine Drives
At Full Speed
With Platform
Raised or
Extended
Be sure boom up drive
limit switch is being
activated by the cam on
the boom when the
boom is raised.
Be sure that the boom
extend drive limit switch
is not being held down
or being activated when
the boom is extended.
Be sure the wiring to
limit switches is intact
and show no signs of
damage or corrosion.
5 - 70
Extend the boom past
the limit switch (LS1)
continuity
and check continuity
from ground to terminal
#6 on the horsepower
limiter board.
no continuity
Check continuity from
continuity Repair open in org wire
ground to TB40.
no continuity
Test limit switches. See
bad
procedure A-14 in the
Maintenance Section.
good
Repair open from wht
wires at TB40 to drive
limit switches (LS1 and
LS2), then from brn
ground wires to ground.
Genie S-60 & Genie S-65
Third Edition • First Printing
Replace horsepower
limiter board OR re-
adjust horsepower
limiter board OR consult
Genie Industries Service
Department.
circuit from TB40 to
TP40 to terminal #6 on
horsepower limiter
board.
Replace faulty limit
switch contact OR
replace limit switch.
Part No. 65196