Genie S-60 Service Manual page 169

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Third Edition • First Printing
Continued from the
previous page.
Part No. 65196
Install a 0 to 5000 PSI
(345 bar) pressure
*SEE
gauge at the quick
NOTE 1
disconnect coupling on
the boom function
manifold and activate
the steer right function.
*SEE
NOTE 2
Repair or replace steer
cylinder OR steer
manifold could have an
internal fault. Consult
Genie Industries Service
Department.
Genie S-60 & Genie S-65
Section 5 • Troubleshooting Flow Charts
Check for mechanical
restrictions keeping
steer right function from
operating OR repair or
replace steer cylinder
OR replace flow
regulator valve (item
WW) OR consult Genie
Industries Service
Department.
CHART 29
*NOTE 1
S-60: 2600 PSI or more
S-65: 2900 PSI or more
*NOTE 2
S-60: Less than
2600 PSI
S-65: Less than
2900 PSI
5 - 63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-65

Table of Contents