Engine Runs While Cranking Then Dies- Gasoline/Lpg Models - Genie S-60 Service Manual

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Section 5 • Troubleshooting Flow Charts
Chart 2A
Engine Runs
While Cranking
Then Dies -
Gasoline/LPG
Models
Be sure to check the
engine oil level and fill
as needed.
Be sure to check fuel
levels and the engine
coolant level.
Be sure that the radiator
overflow tank is at the
mark.
FULL
Perform these tests in
gasoline mode only.
5 - 12
See Repair Section,
How to Retrieve Fault
yes
Codes. Is there a fault
code stored in the ECM
memory?
no
Move the start toggle
0V
switch to either side and
check voltage at
terminal #2 on ignition/
start module.
6 to 7V
Check voltage at
12V
terminal #4 on ignition/
start module.
0V
Replace ignition/start
module OR consult
Genie Industries Service
Department.
Genie S-60 & Genie S-65
Third Edition • First Printing
Check for poor terminal
connections OR check
for shorted or damaged
wires that go from the
ECM to the sensor that
is causing the fault OR
replace the sensor OR
consult Genie Industries
Service Department.
Crank engine and check
0V
voltage at org/blk #41
wire on alternator.
6 to 7V
Repair open in org/blk
#41 wire circuit from
alternator to TB41 to
terminal #2 on ignition/
start module.
Disconnect red wire
12V
from terminal #4 on
ignition/start module and
check voltage at
terminal #4.
0V
Test auxiliary power
toggle switches TS1 and
TS9. See Repair
Section.
Refer to the fault code
chart in this section for
a description of the fault
and recommended
repairs.
Check alternator wiring
OR repair or replace
alternator OR contact
Genie Industries Service
Department.
Replace ignition/start
module OR consult
Genie Industries Service
Department.
Part No. 65196