Perkins Engine - Genie S-60 Service Manual

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Section 2 • Specifications
SPECIFICATIONS

Perkins Engine 704-30

Displacement
Number of cylinders
Bore and stroke
Horsepower
Firing order
Compression ratio
Compression pressure
Pressure (psi) of lowest cylinder must be
within 50 psi (3.45 bar) of highest cylinder
Low idle
High idle
Governor
Valve clearance, cold
Intake
Exhaust
Lubrication system
Oil pressure
(at 2600 rpm)
Oil capacity
(including filter)
Oil viscosity requirements
below 68°F / 20°C (synthetic)
5°F to 104°F / -15°C to 40°C
above 14°F / -10°C
Engine oil should have properties of API classification
CC/SE. API classification CD/SE or CCMC D4 can be
used, but is not recommended during the first 50 hours
or for light load applications.
2 - 6
183 cu in
2.9 liters
4
3.82 x 3.94 inches
97 x 100 mm
63 @ 2600 rpm
1 - 3 - 4 - 2
17.5:1
300 to 500 psi
20.7 to 34.5 bar
1600 rpm
2200 rpm
centrifugal mechanical
0.014 in
0.35 mm
0.014 in
0.35 mm
41 psi
2.8 bar
7.3 quarts
8.3 liters
5W-20
10W-30
15W-40
Genie S-60 & Genie S-65
Injection system
Injection pump make
Injection pump pressure
Injector opening pressure
Fuel requirement
Engine coolant
Capacity
Alternator output
Battery
Type
Quantity
Cold cranking ampere
Reserve capacity @ 25A rate
Fan belt deflection
Third Edition • First Printing
Zexel PFR-KX
2755 psi
190 bar
3626 psi
250 bar
diesel number 2-D
1
11
/
quarts
2
10.9 liters
65A, 12VDC
12VDC, Group 31
1000A
200 minutes
10 mm
Part No. 65196
1
3
/
in
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-65

Table of Contents