Section 4 • Scheduled Maintenance Procedures
TABLE A PROCEDURES
A-21

Inspect the Electrical Wiring

Genie specifications require that
this procedure be performed every
100 hours.
Maintaining electrical wiring in good condition is
essential to safe operation and good machine
performance. Failure to find and replace burnt,
chafed, corroded or pinched wires could result in
unsafe operating conditions and may cause
component damage.
Electrocution hazard. Contact with
hot or live circuits could result in
death or serious injury. Remove all
rings, watches and other jewelry.
1 Open the engine side turntable cover.
2 Remove the 2 engine pivot plate retaining bolts
and swing the engine out away from the
machine to access the wiring.
a
b
a
engine pivot plate
b
pivot plate retaining bolts
c
air baffle
4 - 24
3 Inspect the following areas for burnt, chafed,
4 Open the ground controls side turntable cover.
5 Inspect the following areas for burnt, chafed,
6 Start the engine from the ground controls and
7 Inspect the turntable area for burnt, chafed and
8 Lower the boom to the stowed position and turn
9 Inspect the following areas for burnt, chafed,
10 Swing the engine pivot plate back to its original
c
b
Genie S-60 & Genie S-65
Third Edition • First Printing
corroded and loose wires:
· Engine wiring harness
· Hydraulic manifold wiring
corroded and loose wires:
· Inside of the ground control box
· Hydraulic manifold wiring
raise the boom above the turntable covers.
pinched cables.
the engine off.
corroded, pinched and loose wires:
· Cable track on the primary boom
· Cables on the primary, and jib booms
· Jib boom/platform rotate manifold
· Inside of the platform control box
position and install the two engine pivot plate
retaining bolts.
Part No. 65196