Genie S-60 Service Manual page 115

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Third Edition • First Printing
Continued from the
previous page.
Part No. 65196
Move the start toggle
0V
switch to either side and
check voltage at
terminal #1 on ignition/
start module.
12V
Move the start toggle
0V
switch to either side and
check voltage at
terminal #86 on CR1.
12V
Check voltage at
0V
terminal #30 on CR1.
12V
Move the start toggle
0V
switch to either side and
check voltage at
terminal #87 on CR1.
12V
Move the start toggle
0V
switch to either side and
check voltage at the blk
wire on the starter
solenoid.
12V
Check voltage at starter
0V
cable.
12V
Repair or replace starter
or starter solenoid.
Genie S-60 & Genie S-65
Section 5 • Troubleshooting Flow Charts
Check ground wire to
bad
terminal #5 on ignition/
start module.
good
Consult Genie Industries
Service Department.
Repair open in blk wire
from terminal #1 on
ignition/start module to
CR1.
Repair open in red wire
circuit from battery to
CB1 to CR1 terminal
#30.
Check brn ground wire
bad
to terminal #85 on CR1.
good
Replace CR1 relay.
Repair open in blk wire
circuit from CR1 to
starter solenoid.
Repair open in battery
cable to starter.
CHART 1
Repair open in brn
ground wire to ignition/
start module.
Repair open in brn
ground wire circuit to
CR1.
5 - 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-65

Table of Contents