Section 4 • Scheduled Maintenance Procedures
TABLE C PROCEDURES
5 Use an oil filter wrench and remove the oil filter
located below the fuel filter. Clean the inside of
the filter head.
6 Apply a thin layer of clean engine oil to the new
filter gasket. Install the filter and tighten it
securely by hand.
7 Use a permanent ink marker to write the date
and number of hours from the hour meter on
the oil filter.
8 Fill the engine with new oil per specifications
and install the oil filler cap.
9 Start the engine from the ground controls and
allow the engine to run for 30 seconds. Stop the
engine.
10 Check the oil filter and drain hose for leaks.
11 Wait 15 minutes after stopping the engine and
check the engine oil level on the dipstick. Add
oil if needed.
12 Dispose of the used oil and filter properly.
Perkins 704-30 Engine
Oil capacity (including filter)
Oil viscosity requirements
below 60°F / 15.5°C
-10°F to 90°F / -23°C to 32°C
above -4°F / -34°C
Engine oil should have properties of API classification
CF4 grade.
Oil filter - Genie part number
4 - 58
C-6
Check the Glow Plugs -
Perkins Diesel Models
Complete information to perform this procedure is
available in the Perkins 700 Series Workshop
Manual , Perkins part number TPD 1359E (Genie
part number 62424).
9.6 quarts
9 liters
15W-40
10W-30
15W-40
62422
Genie S-60 & Genie S-65
Third Edition • First Printing
Part No. 65196

Hide quick links: