Third Edition • First Printing
Platform Rotate
Right Function
Inoperative
Be sure all other
functions operate
normally.
Part No. 65196
With key switch turned
to ground controls and
both Emergency Stop
buttons pulled out to the
position, hold the
ON
0V
function enable switch to
either side and move the
platform rotate toggle
switch TS13 in the
RIGHT
direction. Check voltage
at grn/blk-4 wire on
platform rotate right
directional valve
(item CC).
12V or more
Continued on the next
page.
Genie S-60 & Genie S-65
Section 5 • Troubleshooting Flow Charts
With key switch turned
to ground controls and
12V or
both Emergency Stop
more
buttons pulled out to the
position, hold the
ON
function enable switch to
either side and move the
platform rotate toggle
switch in the
RIGHT
direction. Check voltage
at TB18.
0V
With key switch turned
to platform controls and
both Emergency Stop
buttons pulled out to the
position, press down
ON
0V
the foot switch and
move the platform rotate
toggle switch in the
direction. Check
RIGHT
voltage at TB18.
12V or more
Troubleshoot platform
rotate toggle switch
TS13 OR repair open in
red power wire circuit to
TS13 OR repair open in
grn/blk wire circuit from
TS13 to TB18 OR
consult Genie Industries
Service Department.
Chart 24
Repair open in grn/blk-4
wire from TB18 to
platform rotate right
directional valve coil OR
repair open in brn
ground wire circuit to
valve coil.
Troubleshoot platform
rotate toggle switches
TS13 and TS5 OR
repair open in red power
wire circuit to TS13 and
TS5 OR repair open in
grn/blk wire circuit from
TS13 and TS5 to TB18
OR consult Genie
Industries Service
Department.
5 - 53