Section 5 • Troubleshooting Flow Charts
Chart 29
Steer Right
Function
Inoperative
Be sure all other
functions operate
normally.
5 - 62
With key switch turned
to platform controls and
both Emergency Stop
buttons pulled out to the
position, press down
0V
ON
the foot switch and hold
the steer rocker switch
on drive controller in the
direction. Check
RIGHT
voltage on TB37.
12V or more
With key switch turned
to platform controls and
both Emergency Stop
buttons pulled out to the
0V
position, press down
ON
the foot switch and hold
the steer rocker switch
on drive controller in the
direction. Check
RIGHT
voltage on blu/blk #37
wire on steer right
directional valve coil
(item TT) on steer
manifold.
12V or more
0 or
Disconnect wires to
infinite
steer right directional
ohms
valve coil on steer
manifold and test the
resistance of the valve
coil.
5 to 6 ohms
Continued on the next
page.
Genie S-60 & Genie S-65
Third Edition • First Printing
12V or
With key switch turned
more
to platform controls and
both Emergency Stop
buttons pulled out to the
position, press down
ON
the foot switch and hold
the steer rocker switch
on drive controller in the
direction. Check
RIGHT
voltage at the controller
terminal with the blu/blk
wire attached.
0V
Repair or replace steer
microswitch on drive
controller. Consult
Genie Industries Service
Department.
Repair open in blu/blk
#37 wire circuit that runs
from TB37 to steer right
directional valve coil on
steer manifold OR
repair open in brn
ground wire circuit to
steer right valve coil.
Replace steer right
directional valve coil OR
repair open in brn
ground wire circuit to
steer right valve coil.
Repair open in blu/blk
wire circuit from drive
controller to TP37 then
blu/blk-1 to TB37.
Part No. 65196