Fault Code
Problem
11
--
Throttle
Position (TP)
12
sensor low
voltage.
Manifold
Absolute
14
Pressure
(MAP) sensor
low voltage.
Engine speed
21
exceeded
4000 RPM.
Throttle
Position (TP)
22
sensor high
voltage.
Manifold
Absolute
24
Pressure
(MAP) sensor
high voltage.
Part No. 65196
Cause
--
Faulty TP sensor OR
sensor wires shorted to
ground OR poor
terminal connection.
Faulty MAP sensor OR
sensor wires shorted to
ground OR poor
terminal connection.
Obsrtruction in throttle
body OR faulty ECM.
The ECM senses a
signal from the TP
sensor that is greater
than 4.9V DC OR the
TP sensor wiring is
shorted to ground OR
there is a poor terminal
connection OR the TP
sensor is faulty.
Faulty MAP sensor OR
sensor wires shorted to
ground OR poor
terminal connection.
Genie S-60 & Genie S-65
Section 5 • Troubleshooting Flow Charts

Fault Code Chart

Solution
Normal operation
Check for poor terminal connections OR
shorted wires from the TP sencor to the
ECM OR replace the TP sensor.
Check for poor terminal connections OR
wires shorted to ground OR replace MAP
sensor.
Check for obstructions in the throttle body
that could cause binding of the throttle
assembly OR replace ECM.
Check for poor terminal connections OR
shorted wires from the TP sensor to the
ECM OR replace the TP sensor.
Check for poor terminal connections OR
shorted wires from the MAP sensor to the
ECM to ground OR replace MAP sensor.