Engine High Idle Inoperative - Gasoline/Lpg Models - Genie S-60 Service Manual

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Third Edition • First Printing
Engine
High Idle
Inoperative -
Gasoline/LPG
Models
Part No. 65196
See Repair Section,
How to Retrieve Fault
yes
Codes. Is there a fault
code stored in the ECM
memory?
no
Start the engine then
0V
move and hold the RPM
toggle switch to the high
idle (rabbit symbol)
position for the following
tests. Check voltage at
blk/red wire on RPM
select toggle switches
TS4 and TS12.
12V
0V
Check voltage at TB35.
12V
Repair open in tan/blu
wire from TB35 to ECM
OR consult Genie
Industries Service
Department.
Genie S-60 & Genie S-65
Section 5 • Troubleshooting Flow Charts
Check for poor terminal
connections OR check
for shorted or damaged
wires that go from the
ECM to the sensor that
is causing the fault OR
replace the sensor OR
consult Genie Industries
Service Department.
Check voltage at center
0V
terminal on both RPM
select toggle switches.
12V
Replace RPM select
toggle switch.
Repair open in blk/red
wire circuit from toggle
switch to TB35.
Chart 6
Refer to the fault code
chart in this section for
a description of the fault
and recommended
repairs.
Repair open in power
supply circuit to center
terminal of RPM select
toggle switch.
5 - 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-65

Table of Contents