Genie S-60 Service Manual page 171

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Third Edition • First Printing
Continued from the
previous page.
Part No. 65196
Press down the foot
switch and hold the
0V
drive controller in the full
forward position. Check
voltage at terminal #6 on
the drive controller.
9 to 12V
Connect the positive
0V
lead from a voltmeter to
terminal #4 on the drive
controller and the
negative lead to terminal
#5 on the drive
controller. Press down
the foot switch and hold
the drive controller in the
full forward position.
Check voltage across
the #4 and #5 terminals
on the drive controller.
2V
Connect the positive
0V
lead from a voltmeter to
terminal #5 on the drive
controller and the
negative lead to terminal
#4 on the drive
controller. Press down
the foot switch and hold
the drive controller in the
full reverse position.
Check voltage across
the terminals #5 and #4
on the drive controller.
2V
Continued on the next
page.
Genie S-60 & Genie S-65
Section 5 • Troubleshooting Flow Charts
Repair open in wire from
terminal #10 on
horsepower limiter
board to terminal #6 on
the drive controller.
no
Check continuity from
continuity
terminal #3 on drive
controller to ground.
continuity
Replace drive controller
OR consult Genie
Industries Service
Department.
no
Check continuity from
continuity
terminal #3 on drive
controller to ground.
continuity
Replace drive controller
OR consult Genie
Industries Service
Department.
CHART 30
Repair open in brn
ground wire circuit from
terminal #3 on drive
controller to ground.
Repair open in brn
ground wire circuit from
terminal #3 on drive
controller to ground.