Genie S-60 Service Manual page 113

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Third Edition • First Printing
Fault Code
Problem
ECM - Illegal
55
Interuption
ECM -
Computer
56
Operating
Properly
(COP) failure
System
61
voltage low.
System
62
voltage high.
Part No. 65196
Cause
The ECM received an
illegal interruption
signal from one or more
engine sensors and has
gone into a default
program and then
return to normal
operation.
Under normal operation
the ECM will store
numbers into memory.
If this does not happen,
it will reset itself and set
fault code 56.
Battery supply voltage
to the ECM is 8V DC or
less.
Battery supply voltage
to the ECM is 18V DC
or more.
Genie S-60 & Genie S-65
Section 5 • Troubleshooting Flow Charts
Solution
Replace the ECM.
Replace the ECM.
Check battery and/or alternator condition
OR check for shorted wires or poor terminal
connections from the battery to the ECM.
Check battery and/or alternator condition
OR check for shorted wires or poor terminal
connections from the battery to the ECM.