Third Edition • First Printing
Continued from the
previous page.
Part No. 65196
0 or
Disconnect wires to
infinite
boom extend directional
ohms
valve coil (item C) and
test the resistance of the
valve coil. See Repair
Section.
2.5 to 3.5 ohms
function
Hold the function enable
operates Replace faulty
switch to either side and
move the boom extend/
retract toggle switch
TS15 in the
EXTEND
direction. Manually
override the directional
valve by pushing in on
the end of the valve
spool.
function inoperative
Install a 0 to 5000 PSI
2500
(345 bar) pressure
PSI or
gauge at the quick
more
disconnect coupling on
the boom function
manifold and start the
engine. Hold the
function enable switch to
either side and move the
boom extend/retract
toggle switch in the
direction. Check
EXTEND
the pressure.
less than 2500 PSI
function
Exchange boom extend
operates Replace the faulty flow
flow regulator valve
(item G) with boom up/
down flow regulator
valve (item H). Check
boom extend function.
function inoperative
Repair the cylinder or
cylinder counterbalance
valve OR function
manifold could have an
internal fault. Consult
Genie Industries Service
Department.
Genie S-60 & Genie S-65
Section 5 • Troubleshooting Flow Charts
Replace boom extend
directional valve coil.
directional valve.
Check for mechanical
restrictions keeping the
boom from extending
OR repair cylinder or
cylinder counterbalance
valves OR consult
Genie Industries Service
Department.
regulator valve.
CHART 16
5 - 35