Section 4 • Scheduled Maintenance Procedures
TABLE A PROCEDURES
A-13

Test the Tilt Sensor

The tilt sensor sounds an alarm located in the
platform when the incline of the turntable exceeds
the rating on the serial plate.
Select a level test area. The tilt
alarm should not be sounding prior
to the test.
1 Start the engine from the platform controls.
2 Open the tank side turntable cover and press
down on one side of the tilt sensor.
Result: The alarm in the platform should sound.
Tip-over hazard. The alarm should
be audible at the ground controls.
If the alarm is not audible at the
ground controls, replace the alarm
in the platform.
a
a
fuel tank
b
tilt sensor
c
ground control box
4 - 14
b
c
Genie S-60 & Genie S-65
A-14

Test the Limit Switches

Drive Limit Switches
Detecting limit switch malfunctions is essential to
safe machine operation. The drive limit switches
are used to restrict drive speed when the boom is
raised or extended. An improperly functioning drive
limit switch will allow the machine to operate in an
unsafe position.
1 Remove the cover from the rear of the turntable
to access the drive limit switch.
2 Visually inspect the boom up drive limit switch
mounted to the turntable riser at the pivot end
of the boom. Inspect for the following:
· Broken or missing roller or arm
· Missing fasteners
· Loose wiring
a
c
a
turntable riser
b
boom
c
boom up drive limit switch (LS2)
Third Edition • First Printing
b
Part No. 65196