Third Edition • First Printing
2 Remove the 2 engine pivot plate retaining bolts.
Swing the engine pivot plate away from the
machine to access the radiator.
a
b
a
engine pivot plate
b
pivot plate retaining bolts
c
air baffle
3 Inspect the radiator for leaks and physical
damage.
4 Clean the radiator fins of debris and foreign
materials.
5 Inspect all radiator hoses and connections.
6 Swing the engine pivot plate back to its original
position and install the two engine pivot plate
retaining bolts.
7 Replace the air baffle and install the air baffle
retaining fasteners.
Part No. 65196
A-19

Check the Battery

Proper battery condition is essential to good
engine performance and operational safety.
Improper fluid levels or damaged cables and
connections can result in engine component
damage and hazardous conditions.
c
b
1 Put on protective clothing and eye wear.
2 Be sure that the battery cable connections are
3 Be sure that the battery hold downs and cable
Genie S-60 & Genie S-65
Section 4 • Scheduled Maintenance Procedures
TABLE A PROCEDURES
Genie specifications require that
this procedure be performed every
100 hours.
Electrocution hazard. Contact with
hot or live circuits could result in
death or serious injury. Remove all
rings, watches and other jewelry.
Bodily injury hazard. Batteries
contain acid. Avoid spilling or
contacting battery acid. Neutralize
battery acid spills with baking soda
and water.
free of corrosion.
connections are tight.