Test the Alarm Package
(if equipped)
The alarm package includes:
· Travel alarm
· Descent alarm
· Flashing beacons
Alarms and beacons are installed to alert operators
and ground personnel of machine proximity and
motion. The alarm package is installed on the
turntable rear cover. Beacons are installed on both
turntable covers.
The alarms and beacons will
operate with the engine
running or not running.
1 Turn the key switch to ground controls and pull
out the Emergency Stop button to the
position at both the ground and platform
controls.
Result: Both flashing beacons should be
flashing.
2 Hold the function enable switch to either side
and activate the boom toggle switch in the
position, hold for a moment and then release it.
Result: The descent alarm should sound when
the toggle switch is held down.
3 Turn the key switch to platform controls.
Result: The flashing beacons should be
and flashing.
Part No. 65196
Section 4 • Scheduled Maintenance Procedures
4 Move the lift/drive selector switch to the lift
position (if equipped).
5 Press down the foot switch. Move the boom
controller to the
moment and then release it.
Result: The descent alarm should sound when
the controller is held down.
6 Move the lift/drive selector switch to the drive
position (if equipped).
7 Press down the foot switch. Move the drive
controller off center, hold for a moment and
then release it. Move the drive controller off
center in the opposite direction, hold for a
moment and then release it.
Result: The travel alarm should sound when the
drive controller is moved off center in either
direction.
ON
and
ON
DOWN
ON
Genie S-60 & Genie S-65
TABLE B PROCEDURES
position, hold for a
DOWN
4 - 47