11 Install the new fuel pressure regulator/filter
(Genie part number 52567) onto the engine
mounting leg and connect the hoses to the
regulator/filter.
Component damage hazard. Be
sure the correct regulator/filter is
installed or component damage
may occur.
12 Turn the manual shutoff valve, located at the
fuel tank, to the
OPEN
13 Start the machine from the ground controls,
then inspect the fuel filters and hoses for leaks.
Explosion and fire hazard. If a fuel
leak is discovered, keep any
additional personnel from entering
the area and do not operate the
machine. Repair the leak
immediately.
14 Swing the engine pivot plate back to its original
position and install the two engine pivot plate
retaining bolts.
Part No. 65196
position.