SPN
FMI
Short Text Detail
132
11
Air flow sensor load correction factor exceeding the maximum drift limit; plausibility error
132
11
Air flow sensor load correction factor exceeding drift limit; plausibility error
132
11
Air flow sensor low idle correction factor exceeding the maximum drift limit
132
11
Air flow sensor load correction factor exceeding the maximum drift limit
172
2
Sensor ambient air temperature; plausibility error
523006
3
Controller mode switch; short circuit to battery
523006
4
Controller mode switch; short circuit to ground
168
3
Sensor error battery voltage; signal range check high
168
4
Sensor error battery voltage; signal range check low
168
2
High battery voltage; warning threshold exceeded
168
2
Low battery voltage; warning threshold exceeded
597
2
Break lever mainswitch and break lever redundancyswitch status not plausible
523910
14
Air pump doesn´t achieve air mass flow setpoint
524013
7
Burner flame unintentional deleted
524020
14
Engine power; Not enough oxygen for regeneration
523911
0
Burner dosing valve (DV2); overcurrent at the end of the injection phase
523911
12
Burner dosing valve (DV2); powerstage over temperature
523911
3
Burner dosing valve (DV2); short circuit to battery
523911
3
Burner dosing valve (DV2); short circuit to battery on high side
523911
4
Burner dosing valve (DV2); short circuit to ground
523911
11
Burner dosing valve (DV2); short circuit high side powerstage
523912
2
Burner dosing valve (DV2) downstream pressure sensor; plausibility error
523912
0
Physical range check high for burner dosing valve (DV2) downstream pressure; shut off regeneration
523912
1
Physical range check low for burner dosing valve (DV2) downstream pressure; shut off regeneration. When burner injector is
actuated, the measured pressure does not rise above ca. 1250mbar abs (expected: ca. 2400mbar).
523912
3
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range check high
523912
4
Sensor error burner dosing valve (DV2) downstream pressure sensor; signal range check low
523913
3
Sensor error glow plug control diagnostic line voltage; signal range check high
523913
4
Sensor error glow plug control diagnostic line voltage; signal range check low
523914
5
Glow plug control; open load
523914
12
Glow plug control; powerstage over temperature