Test the Auxiliary Power
Operation
Detection of auxiliary power system malfunctions is
essential for safe machine operation. An unsafe
working condition exists if the auxiliary powered
functions do not operate in the event of a main
power loss. When operating the machine on
engine power, selecting auxiliary power will stop
the engine immediately. Auxiliary power is
designed for short term use only, and excessive
use will result in battery drain and component
damage.
1 Turn the key switch to ground control and pull
out the Emergency Stop button to the
position.
2 Lift the red auxiliary power
toggle switch cover
(if equipped).
3 Simultaneously hold the
auxiliary power toggle switch
and activate each boom
ON
function toggle switch.
Result: All boom functions should operate.
To conserve battery power, test
each function through a partial
cycle.
4 Turn the key switch to platform control.
5 Pull out the Emergency Stop button to the
position at the platform controls, then press
down the foot switch.
Part No. 65196
Section 4 • Scheduled Maintenance Procedures
6 Lift the red auxiliary power toggle switch cover if
equipped).
7 Simultaneously
hold the
auxiliary power
toggle switch
and activate
ON
each function
controller or
toggle switch.
Result: All boom and steer functions should
operate. Drive functions should not operate with
auxiliary power.
ON
ON
Genie S-60 & Genie S-65
TABLE A PROCEDURES
To conserve battery power, test
each function through a partial
cycle.
4 - 13