Section 4 • Scheduled Maintenance Procedures
TABLE C PROCEDURES
C-2
Check the Engine Valve
Clearances -
Deutz Diesel Models
Engine specifications require
that this procedure be performed
initially at 500 hours, at 1000
hours and every 1000 hours
thereafter.
Complete information to perform this procedure is
available in the Deutz F4L 1011F Operation
Manual , Deutz part number 0297 7343 (Genie part
number 52883).
4 - 54
C-3
Replace the Fuel Filter/ Water
Separator Element -
Perkins Diesel Models
Replacing the diesel fuel filter/water separator
element is essential for good engine performance
and service life. A dirty or clogged filter may cause
the engine to perform poorly and continued use
may cause component damage. Extremely dirty
conditions may required that the filter be replaced
more often.
1 Open the engine side turntable cover and locate
the fuel filter/water separator.
2 Tag, disconnect and plug the fuel hose from the
fuel tank at the fuel filter/water separator head.
Genie S-60 & Genie S-65
Third Edition • First Printing
Explosion and fire hazard. Engine
fuels are combustible. Perform this
procedure in an open, well-
ventilated area away from heaters,
sparks, flames and lighted
tobacco. Always have an
approved fire extinguisher within
easy reach.
Perform this procedure with the
engine off.
Immediately clean up any fuel that
may have spilled during this
procedure.
Part No. 65196