FUEL AND HYDRAULIC TANKS
9 Remove the retaining fasteners from the
hydraulic tank hold down straps. Remove the
hold down straps from the hydraulic tank.
10 Support the hydraulic tank with 2 lifting straps.
Place one lifting strap at each end of the tank
and attach the lifting straps to an overhead
crane.
11 Remove the hydraulic tank from the machine.
Crushing hazard. The hydraulic
tank could become unbalanced
and fall if it is not properly
supported and secured to the
overhead crane.
12 Remove the suction strainers from the tank and
clean them using a mild solvent.
13 Rinse out the inside of the tank using a mild
solvent.
14 Install the suction strainers using pipe thread
sealant on the threads.
15 Install the drain plug using pipe thread sealant
on the threads.
16 Install the hydraulic tank onto the machine.
17 Install the two suction hoses and the supply
hose for the auxiliary power unit.
18 Fill the tank with hydraulic oil until the level is
within the top 2 inches (5 cm) of the sight
gauge. Do not overfill.
7 - 66
19 Clean up any oil that may have spilled.
20 Open the hydraulic tank shutoff valves.
Hydraulic system
Hydraulic tank capacity
Hydraulic system
capacity (including tank)
Hydraulic fluid
Genie S-60 & Genie S-65
Third Edition • First Printing
Component damage hazard.
Be sure to open the two hydraulic
tank shutoff valves and prime the
pump after installing the hydraulic
tank.
Always use pipe thread sealant
when installing the drain plug and
strainers.
Use only Dexron equivalent
hydraulic fluid.
Dexron equivalent
Part No. 65196
45 gallons
170 liters
55 gallons
208 liters