Genie S-60 Service Manual page 179

Hide thumbs Also See for S-60:
Table of Contents

Advertisement

Third Edition • First Printing
Continued from the
previous page.
Part No. 65196
bad
Test PR1. See Repair
Procedure 8-5.
good
12V or
Move the auxiliary pump
more
toggle switch to either
side and check voltage
at TB27.
0V
Move the auxiliary pump
0V
toggle switch to either
side and check the
voltage at the center
terminal of TS9.
12V or more
Repair open in red #27
wire from TS9 to TB27
OR replace TS9.
Genie S-60 & Genie S-65
Section 5 • Troubleshooting Flow Charts
Replace PR1.
Repair open from TB27
to PR1 OR repair open
in brn ground wire circuit
to PR1 OR replace PR1.
Repair open in red
power supply wire from
key switch to auxiliary
pump toggle switch.