How to Remove the Turntable
Rotation Brake or Drive Hub
1 Secure the turntable from rotating with the
turntable rotation lock pin.
unlocked
2 Remove the motor, See 13-1, How to Remove
the Rotation Hydraulic Motor .
Component damage hazard.
Hoses can be damaged if they are
kinked or pinched.
a
motor
b
motor/brake mounting bolts
c
brake
d
drive hub
e
drive hub mounting bolts
Part No. 65196
3 Remove the drive hub mounting bolts, then use
4 Install the drive hub. Torque the drive hub
5 Install the brake, then motor onto the drive hub.
6 Adjust turntable rotation gear backlash. See
locked
Genie S-60 & Genie S-65
Section 7 • Repair Procedures
TURNTABLE ROTATION COMPONENTS
an appropriate lifting device to remove the drive
hub from the machine.
Crushing hazard. The turntable
rotate drive hub could become
unbalanced and fall when it is
removed from the machine if it is
not properly supported.
mounting bolts to 180 ft-lbs (244 Nm).
Torque the brake/motor mounting bolts to
75 ft-lbs (102 Nm).
13-1, How to Adjust the Turntable Rotation
Gear Backlash.