Show Chassis Alarms - Juniper JUNOS OS 10.3 - SOFTWARE Manual

For ex series ethernet switches
Hide thumbs Also See for JUNOS OS 10.3 - SOFTWARE:
Table of Contents

Advertisement

show chassis alarms

Syntax
Syntax (TX Matrix
Router)
Syntax (TX Matrix Plus
Router)
Release Information
Description
Options
Additional Information
Required Privilege
Level
List of Sample Output
Copyright © 2010, Juniper Networks, Inc.
show chassis alarms
show chassis alarms
<lcc number | scc>
show chassis alarms
<lcc number | sfc number>
Command introduced before Junos OS Release 7.4.
Command introduced in Junos OS Release 9.0 for EX Series switches.
sfc
option for the TX Matrix Plus router introduced in Junos OS Release 9.6.
Display information about the conditions that have been configured to trigger alarms.
—Display information about the conditions that have been configured to trigger
none
alarms.
— (TX Matrix and TX Matrix Plus routers only) (Optional) On the TX Matrix
lcc number
router, show information about a specified T640 router (or line-card chassis) that
is connected to the TX Matrix router. On the TX Matrix Plus router, show information
about a specified T1600 router (or line-card chassis) that is connected to the TX
Matrix Plus router. Replace
—(TX Matrix router only) (Optional) Show information about the TX Matrix router (or
scc
switch-card chassis).
sfc number
—(TX Matrix Plus router only) (Optional) Show information about the TX
Matrix Plus router (or switch-fabric chassis). Replace
You cannot clear the alarms for chassis components. Instead, you must remedy the
cause of the alarm. When a chassis alarm is lit, it indicates that you are running the router
or switch in a manner that we do not recommend.
On the routers, you can manually silence external devices connected to the alarm relay
contacts by pressing the alarm cutoff button, located on the craft interface. Silencing
the device does not remove the alarm messages from the display (if present on the
router) or extinguish the alarm LEDs. In addition, new alarms that occur after you silence
an external device reactivate the external device.
view
show chassis alarms (Alarms Active) on page 748
show chassis alarms (No Alarms Active) on page 748
show chassis alarms (Alarms Active on a TX Matrix Router) on page 748
show chassis alarms (Backup Routing Engine) on page 749