Table 6: Show Redundancy Output Fields - Juniper SERVICE AVAILABILITY - CONFIGURATION GUIDE V 11.1.X Configuration Manual

Software for e series broadband services routers service availability configuration guide
Table of Contents

Advertisement

Table 6: show redundancy Output Fields

Field Name
SRP
high-availability state
current redundancy mode
last activation type
Criteria Preventing High
Availability from being Active
Criteria Required for High
Availability to be Active
Line Card
automatic reverting
Chapter 3: Managing Stateful SRP Switchover
Field Description
State of high availability mode:
disabled Initial, default state for
high-availability mode. The router continues to
use file system synchronization.
active Data synchronized from the active SRP
module to the standby SRP module during
initialization remains synchronized through
mirroring updates.
pending If an unsupported application is
configured, the router transitions to this state.
initializing If SRP module is in initializing state,
bulk synchronization of memory and NVS
occurs.
Redundancy mode currently used by the router:
high-availability Ensures rapid SRP module
recovery after a switchover by using initial bulk
file transfer and subsequent, transaction-based
mirroring.
file-system-synchronization Default
redundancy mode of the router. SRP modules
reload all line modules and restart form saved
configuration files.
Last type of activation that occurred on the router.
The method using which the SRP last booted:
cold-switch When the router is in pending state
and switchover occurs, the router undergoes a
cold-switch or cold re-start.
warm-switch When the router is in active state
and switchover occurs, the router undergoes a
warm-switch or warm re-start.
Criteria preventing the router from being in the active
state of high availability mode.
NOTE: For the router to be in the Active state, all
criteria for this option must be "yes".
Criteria required for the router to be in the active
state of high availability mode.
NOTE: For the router to be in the Active state, all
criteria for this option must be "yes".
State of automatic reverting. Possible states: on or
off.