Verify on an EX8200 switch:
What the power redundancy and line card priority settings are
Whether the N+1 or N+N power requirements are being met
Whether the switch has sufficient power for a new line card or an N+N configuration
Enter the following command:
user@switch> show chassis power-budget-statistics
PSU
1
(EX8200-AC2K)
PSU
2
(EX8200-AC2K)
PSU
3
(EX8200-AC2K)
PSU
4
(EX8200-AC2K)
Total Power supplied by all Online PSUs
Power Redundancy Configuration
Power Reserved for the Chassis
FPC
5
(EX8200-48F )
FPC
6
(EX8200-8XS )
Actual Power Used
Power Available (Redundant case)
Total Power Available
The switch is configured for N+N redundancy. As shown by the
(Redundant case)
field, the switch has sufficient power to meet the N+N power
requirements and has an additional 420 W available. The switch has insufficient power
for an additional 8-port SFP+ line card while maintaining N+N redundancy, because the
line card requires 450 W. However, it does have enough power for an additional 48-port
SFP line card, which requires only 330 W. The 8-port SFP+ line card in slot 6 has a higher
power priority than the 48-port SFP line card line card in slot 5.
:
1200 W
:
1200 W
:
1200 W
:
1200 W
:
4800 W
:
N+N
:
1200 W
:
330 W
Priority: 7
:
450 W
Priority: 0
:
1980 W
:
420 W
:
2820 W
Power Available