Four EX4200-24P switches (SWA-2, SWA-3, SWA-4, and SWA-5) with 24 access
ports, all of which support PoE
Figure 18 on page 959 shows that all the member switches are interconnected with the
dedicated VCPs on the rear panel. The LCD on the front displays the member ID and role.
Figure 18: Default Configuration of Multimember Virtual Chassis in a Single
Wiring Closet
Configure a multimember Virtual Chassis access switch in a single wiring closet using
the factory defaults:
By default, after you interconnect the switches with the dedicated VCPs and power on
the switches, the VCPs are operational. The mastership priorities and member IDs are
assigned by the software. To determine which switch has been selected as the master,
check the LCD on the front panel. It should be the first switch that you power on. The
backup should be the second switch that you power on. The other switches are all
linecards. Wait at least one minute after powering on the master, before continuing to
power on the other switches.
To configure a multimember Virtual Chassis with default role assignments:
Make sure the dedicated VCPs on the rear panel are properly cabled. See Virtual
1.
Chassis Cabling Configuration Examples for EX4200 Switches for additional
information.
Power on the switch that you want to function as the master (SWA-0). This
2.
examples uses one of the larger switches (EX4200-48P) as the master.
Check the front panel LCD to confirm that the switch has powered on correctly and
3.
that a member ID has been assigned.
Chapter 44: Virtual Chassis—Configuration Examples
959