Juniper JUNOS OS 10.3 - SOFTWARE Manual page 1092

For ex series ethernet switches
Hide thumbs Also See for JUNOS OS 10.3 - SOFTWARE:
Table of Contents

Advertisement

Complete Software Guide for Junos
Step-by-Step
Procedure
Results
Verification
Purpose
Action
Meaning
Related
Documentation
996
®
OS for EX Series Ethernet Switches, Release 10.3
[edit]
set virtual-chassis fast-failover ge
To configure fast failover on SFP uplink module VCPs:
Enable fast failover on all SFP uplink module VCPs in the Virtual Chassis
1.
configuration:
[edit]
user@switch1# set virtual-chassis fast-failover ge
NOTE: We recommend that you use the
to save any configuration changes that you make to a multimember
Virtual Chassis.
Check the results of the configuration:
[edit virtual-chassis]
user@switch1# show
fast-failover {
ge;
}
To confirm that fast failover is enabled on SFP uplink module VCPs in the Virtual Chassis
configuration, perform these tasks:
Verifying That Fast Failover Is Enabled on page 996
Verifying That Fast Failover Is Enabled
Verify that fast failover has been enabled in a Virtual Chassis configuration.
Issue the
show virtual-chassis fast-failover
1.
Check to see that fast failover is enabled.
2.
user@switch1> show virtual-chassis fast-failover
Fast failover on dedicated VCP ports: Enabled
Fast failover on XE uplink VCP ports: Disabled
Fast failover on GE uplink VCP ports: Enabled
Fast failover is enabled on all dedicated VCPs and SFP uplink module VCPs in the Virtual
Chassis configuration.
Configuring Fast Failover in a Virtual Chassis Configuration on page 1029
commit synchronize
command.