management then allocates 4000 W to redundant power. If a power supply goes offline
again, power management once again allocates 2000 W to redundant power.
When power is insufficient to meet the budgeted power requirements, power management
raises alarms as follows:
If all the line cards are receiving power but insufficient redundant power exists to
maintain the configured N+1 or N+N power configuration, power management raises
a minor (yellow) alarm. If this condition persists for 5 minutes, the alarm becomes a
major (red) alarm.
If one or more line cards are down because of insufficient power (including redundant
power), power management raises a major (red) alarm.
Power management clears all alarms when sufficient power is available to meet normal
operating and redundant power requirements.