Reverting to the Rescue Configuration for the EX Series Switch

Copyright © 2010, Juniper Networks, Inc.
Use the LCD panel to revert to the default factory configuration if you want to run EZsetup.
When you use the CLI to revert to the default factory configuration, the configuration for
the root password is retained and you cannot run EZSetup.
NOTE: The
load factory default
EX4200 switches configured in a Virtual Chassis with multiple members. In
a multimember Virtual Chassis configuration, you can revert to the default
factory configuration while retaining the Virtual Chassis parameters (member
ID, mastership priority, or settings of VCP uplinks) using the following
procedure:
[edit]
1.
user@switch# load factory default
[edit]
2.
user@switch# delete system commit factory-settings
[edit]
3.
user@switch# commit
Check the member ID and mastership priority with the
4.
command and check to see whether there are remaining settings
status
for uplink VCPs by using the
Configuring a Virtual Chassis (CLI Procedure) on page 1011
EX2200 Switch Default Configuration on page 401
EX3200 and EX4200 Default Configuration on page 405
EX4500 Default Configuration on page 409
EX8200 Switch Default Configuration on page 415
Understanding Configuration Files for EX Series Switches on page 397
For more information about the
User Guide at
http://www.juniper.net/techpubs/software/junos/index.html
If someone inadvertently commits a configuration that denies management access to
an EX Series switch and the console port is not accessible, you can overwrite the invalid
configuration and replace it with the rescue configuration by using the LCD panel on the
switch. The rescue configuration is a previously committed, valid configuration.
You can also revert to the default factory configuration, as described in "Reverting to the
Default Factory Configuration for the EX Series Switch" on page 427.
Before you begin to revert to the rescue configuration:
Ensure that you have physical access to the switch.
Chapter 24: Managing Junos OS Configuration
command by itself is not supported on
show virtual-chassis vc-port
command see the Junos OS CLI
load factory default
show virtual-chassis
command.
.