Juniper JUNOS OS 10.3 - SOFTWARE Manual page 1338

For ex series ethernet switches
Hide thumbs Also See for JUNOS OS 10.3 - SOFTWARE:
Table of Contents

Advertisement

Complete Software Guide for Junos
Table 179: show interfaces diagnostics optics Output Fields (continued)
Field Name
Laser rx power low alarm threshold
Laser rx power high warning threshold
Laser rx power low warning threshold
show interfaces
show interfaces
diagnostics optics
diagnostics optics
ge-0/1/0
ge-0/1/0
(SFP Transceiver)
(SFP Transceiver)
1242
®
OS for EX Series Ethernet Switches, Release 10.3
Field Description
Displays the vendor-specified threshold for the laser rx power low alarm.
Displays the vendor-specified threshold for the laser rx power high
warning.
Displays the vendor-specified threshold for the laser rx power low
warning.
user@host> show interfaces diagnostics optics ge-0/1/0
Physical interface: ge-0/1/0
Laser bias current
Laser output power
Module temperature
Module voltage
Receiver signal average optical power
Laser bias current high alarm
Laser bias current low alarm
Laser bias current high warning
Laser bias current low warning
Laser output power high alarm
Laser output power low alarm
Laser output power high warning
Laser output power low warning
Module temperature high alarm
Module temperature low alarm
Module temperature high warning
Module temperature low warning
Module voltage high alarm
Module voltage low alarm
Module voltage high warning
Module voltage low warning
Laser rx power high alarm
Laser rx power low alarm
Laser rx power high warning
Laser rx power low warning
Laser bias current high alarm threshold
Laser bias current low alarm threshold
Laser bias current high warning threshold :
Laser bias current low warning threshold
Laser output power high alarm threshold
Laser output power low alarm threshold
Laser output power high warning threshold :
Laser output power low warning threshold
Module temperature high alarm threshold
Module temperature low alarm threshold
Module temperature high warning threshold :
Module temperature low warning threshold
Module voltage high alarm threshold
Module voltage low alarm threshold
Module voltage high warning threshold
Module voltage low warning threshold
Laser rx power high alarm threshold
Laser rx power low alarm threshold
:
5.444 mA
:
0.3130 mW / -5.04 dBm
:
36 degrees C / 97 degrees F
:
3.2120 V
:
0.3840 mW / -4.16 dBm
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
Off
:
15.000 mA
:
1.000 mA
12.000 mA
:
2.000 mA
:
0.6300 mW / -2.01 dBm
:
0.0660 mW / -11.80 dBm
0.6300 mW / -2.01 dBm
:
0.0780 mW / -11.08 dBm
:
109 degrees C / 228 degrees F
:
-29 degrees C / -20 degrees F
103 degrees C / 217 degrees F
:
-13 degrees C / 9 degrees F
:
3.900 V
:
2.700 V
:
3.700 V
:
2.900 V
:
1.2589 mW / 1.00 dBm
:
0.0100 mW / -20.00 dBm