trigger (on | after | until) event-count;
[edit event-options policy policy-name within seconds]
Statement introduced in Junos OS Release 8.4.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Configure an event policy to be triggered if an event or set of events occurs
times within a specified time period.
If you do not include this statement, the policy is executed on receipt of the first configured
event.
—The policy is executed when the number of matching events received
after event-count
equals
event-count
+ 1.
—The policy is executed when the number of matching events received
on event-count
equals
event-count
.
—The policy is executed each time a matching event is received and
until event-count
stops being executed when the number of matching events received equals
event-count
.
maintenance—To view this statement in the configuration.
maintenance-control—To add this statement to the configuration.
Triggering an Event Policy Based on Event Count
event-count