Juniper JUNOS OS 10.3 - SOFTWARE Manual page 1168

For ex series ethernet switches
Hide thumbs Also See for JUNOS OS 10.3 - SOFTWARE:
Table of Contents

Advertisement

Complete Software Guide for Junos
request virtual-chassis vc-port
Syntax
Release Information
Description
Options
Additional Information
Required Privilege
Level
Related
Documentation
List of Sample Output
request virtual-chassis
request virtual-chassis
vc-port set pic-slot 1
vc-port set pic-slot 1
port 0
port 0
request virtual-chassis
vc-port set pic-slot 1
port 1 member 3
request virtual-chassis
vc-port delete pic-slot
1 port 1 member 3
1072
®
OS for EX Series Ethernet Switches, Release 10.3
request virtual-chassis vc-port set | delete pic-slot pic-slot port port-number
<member member-id>
Command introduced in Junos OS Release 9.0 for EX Series switches.
Enable or disable an uplink module port (on an SFP, SFP+, or XFP uplink module) or an
SFP network port on an EX4200-24F switch as a Virtual Chassis port (VCP).
pic-slot pic-slot
—Number of the PIC slot for the uplink module port or SFP network port
on an EX4200-24F switch. Specify
Series switch. Specify
—Number of the uplink module port (
port port-number
EX4200-24F switch (
member member-id
—(Optional) Enable or disable the specified VCP on the specified
member of the Virtual Chassis configuration.
If you omit
member member-id
VCP or SFP network port configured as a VCP on the switch where the command is
issued.
system-control
request virtual-chassis vc-port on page 1073 (dedicated port)
show virtual-chassis vc-port on page 1083
show virtual-chassis vc-port statistics on page 1086
clear virtual-chassis vc-port statistics on page 1068
Understanding Virtual Chassis Components on page 924
request virtual-chassis vc-port set pic-slot 1 port 0 on page 1072
request virtual-chassis vc-port set pic-slot 1 port 1 member 3 on page 1072
request virtual-chassis vc-port delete pic-slot 1 port 1 member 3 on page 1072
user@host>request virtual-chassis vc-port set pic-slot 1 port 0
To check the results of this command, use the show virtual-chassis vc-port command.
user@host>request virtual-chassis vc-port set pic-slot 1 port 1 member 3
To check the results of this command, use the show virtual-chassis vc-port command.
user@host>request virtual-chassis vc-port delete pic-slot 1 port 1 member 3
To check the results of this command, use the show virtual-chassis vc-port command.
to represent the uplink module PIC on the EX
1
0
to represent the SFP network port on an EX4200-24F switch.
to
) that is to be enabled or disabled as a VCP.
0
23
, this command defaults to enabling or disabling the uplink
or
) or SFP network port on an
0
1
Copyright © 2010, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Table of Contents